- 200V-240V Input, Switched Single-Phase 30A rack Power Distribution Unit.
- Input: NEMA L6-30P (5.0 kW).
- Output Receptacles: Twenty-One (21) C13 Outlets, and three (3) C19 Outlets.
- 0U Vertical ing PDU.
- Cord Length: 9.8inches.
Product Description
-------------------
APC AP8941 Rack PDU 2G/ Switched/ Zero U/ 30A/ 208V Surge
Protector
From the Manufacturer
---------------------
Superior Equipment and Data Protection
--------------------------------------
Why buy APC by Schneider Electric?
----------------------------------
Over the years, APC by Schneider Electric has received hundreds
of awards worldwide - more than any other power protection
manufacturer. Such designations have recognized APC by Schneider
Electric for both its reliable solutions and its overall business
performance.
Rack PDU 2G, Switched, ZeroU, 30A, 200/208V, (21) C13 & (3) C19
-----------------------------------------------------------------
Switched Rack PDUs provide advanced load monitoring combined with
remote on/off sw control of individual outlets for power
cycling, delayed power sequencing, and outlet use management.
APC by Schneider Electric Switched Rack Power Distribution Units
(PDUs) enable advanced, user-customizable power control and
active monitoring. Remote outlet level controls allow power
on/off functionality for power cycling to remotely reboot
equipment and restrict unauthorized use of individual outlets.
Power sequencing time delays allow users to define the order in
which to power up or down attached equipment to avoid circuit
overload. Current metering provides real-time remote monitoring
of connected loads with user-defined alarms to warn of potential
circuit overloads. New AP8000 series Metered Rack PDUs include
real power monitoring, a temperature/humidity sensor port,
locking IEC receptacles, and ultra low profile circuit breakers.
User-defined alarms warn of potential circuit overloads before
critical IT failures occur. Users can access, configure, and
control Switched Rack PDUs through secure Web, SNMP, Command Line
Interface, or Telnet Interfaces which are complimented by
Schneider Electric's StruxureWare solution.
Switched Rack PDU Features & Benefits Availability Network
Management Full-featured network management interfaces that
provide standards-based management via Web, SNMP, and Telnet.
Allows users to access, configure, and manage units from remote
locations to save valuable time. Associated with this feature is
the ability to quickly and easily upgrade the firmware via
network download to installed units for future product
enhancements. Remote Management Capabilities Full-featured
network management interfaces that provide standards-based
management via Web, SNMP, and Telnet. Allows users to access,
configure, and manage units from remote locations to save
valuable time. Associated with this feature is the ability to
quickly and easily upgrade the firmware via network download to
installed units for future product enhancements. Alarm Thresholds
Define alarm thresholds in order to avoid overloaded circuits.
Network and visual alarms inform the user of possible problems.
(Note: Only available on units with the current monitoring
capabilities. Please see SKU specifications for availability)
Local Current Monitoring Display The aggregate current draw per
power distribution unit is displayed on the unit via a digital
display. The local digital display helps installers avoid
overloaded circuits by providing a visible warning when the
current draw is close to the maximum amperage draw of the strip.
(Available on designated SKUs only) Power Delays Allows users to
configure the sequence in which power is turned on or off for
each outlet. This helps avoid in-rushes at start-up, which can
cause overloaded circuits and dropped loads. Sequencing also
allows users to predetermine which piece of equipment is turned
on first so other equipment dependant on that unit will function
properly. Load indicator LED Indicates overload and warning
conditions based on the user-defined alarm thresholds. Alerts
users of potential overloaded circuits. Flash Upgradeable Quickly
and easily upgrade firmware via network download for future
product enhancements. Eliminates the need to replace products
already installed in the field when new features are released.
(Note: Networked units only)
Technical Specifications Output Nominal Output Voltage 200V,
208V Maximum Total Current Draw per Phase 30A Output Connections
(21) IEC 320 C13 (3) IEC 320 C19 Overload Protection Yes Input
Nominal Input Voltage 200V, 208V, 230V Input Frequency 50/60 Hz
Regulatory Derated Input Current (North America) 24A Input
Connections NEMA L6-30P Cord Length 3.05 meters Number of Power
Cords 1 Maximum Line Current per phase 30A Maximum Input Current
per phase 30A Physical Net Weight 7.64 kg Maximum Height 1829.00
mm Maxiumum Width 56.00 mm Maximum Depth 46.00 mm Shipping Weight
10.00 kg Shipping Height 2040.00 mm Shipping Width 165.00 mm
Shipping Depth 124.00 mm Color Black Environmental Operating
Environment -5 - 45 °C Operating Relative Humidity 5 - 95%
Operating Elevation 0 - 3000 meters Storage Temperature -25 - 65
°C Storage Relative Humidity 5 - 95% Storage Elevation 0 - 15,000
meters Conformance Regulatory Approvals cUL Listed, FCC Part 15
Class A, ICES-003, PSE, UL Listed, VCCI Class A Standard Warranty
2 years repair or replace Sustainable Offer Status RoHS Compliant
REACH REACH: Contains No SVHCs Battery Directive Compliant
Battery Notes Contains Lithium Battery